Includes the Installation of the Unit, the Refrigeration Pipe Work, the Electrical Work for the connection of the unit, Commissioning of the unit and 12 Month Warrantee on the Installation. Does not include: Switchboard alteration or Upgrade if Required and Manufacturers Warrantee is covered by the Manufacturer.

Sizing of the Unit:
First, What size is the House? Measure the total area of the house then multiply by 0.8 to take out bathrooms etc. so if you have 170M2 x 0.8 = 136M2.

Then determine the heat load, Light (145 Watts/M2) , Normal (155 Watts/M2), or very hot (180 Watts/M2) in summer. Think about how hot your house gets in summer this will assist you here.

Once you know this you then need to know what you likely Maximum area is that you will have on at any given time, say 70% of that area.

So; 136 M2 x 0.7 = 95 M2. So take the 95 x (medium heat Load @155 Watts/M2) = 14725Watts / 1000 = 14.7KW.

Remember that you need to work out the maximum area that you will be cooling before you decide on the area in this table, a common mistake is to oversize. Please refer to the steps above.
Approx Size of Unit Up to 70m2 70M2 to 90M2 90M2 to 120M2 120M2 to 160M2 160M2 to 200M2
Low Heat Load 7KW 10KW 12KW 14KW 19KW
Med Heat Load 8KW 12KW 14KW 17KW 22KW
High Heat Load 10KW 12KW 14KW 19KW 25KW

Disclaimer:
We always recommend that a professional call and measure your home correctly taking into account the not so obvious heat sources, this will ensure you purchase the correct size unit the first time round.

Features of Mitsubishi Electric Power Inverter Ducted Air Conditioning Systems - Follow this link

  • AIRCONDITIONING UNIT (INVERTERS)
    SELECTED:
    Mitsubishi PEA-RP100EA Min 4.9 - Max 11.4 KW
    $4,365.00
  • DUCTWORK (OUTLETS)
    SELECTED:
    Number of Outlets 7 off
    $2,765.00
  • INSTALLATION AND MATERIALS
    SELECTED:
    10 - 12 KW System up to 6 outlets
    $3,000.00
  • REMOVE OLD EVAPORATIVE COOLER FROM ROOF
    SELECTED:
    Remove Old Evaporative Cooler and Patch Roof (tiles supplied)
  • PATCH HOLES AFTER EVAP COOLER REMOVAL (SOME HOLES CAN BE REUSED)
    SELECTED:
    Patch 1 - 2 Holes ready to paint by others
  • INSULATION & VACCUM CEILING
    SELECTED:
    Remove insulation, Vac ceiling and replace insulation (small house)
Total: $10,130.00
 
Located at 78 Essington Lewis Ave Whyalla - Open 8.30AM - 5PM Weekdays
Located at Moran St Whyalla, Open 8AM - 5PM Weekdays - Window, Security Doors, Roller Doors, Roller Shutters, Kitchens, Building Work
HIA Members
Home   |   About Us   |   Online Store   |   Services   |   Contact Us   |   Privacy   |   Disclaimer   |   Your Account   |   Shipping Information   |   Customer Service & Refunds   |   Security Policy   |   Links
© NJ & T McMullen 2019   |   ABN: 29 008 166 747   |   Builders license: BLD 54620   |   Website by Static Fiction